CHENGLIWEI
Chengliwei 20m3 10-Ton Mobile LPG Auto Filling Station
Chengliwei mobile LPG auto filling station: dispenser, 5-30m3 propane tanks, 1.77 MPa, free spares for 12 months. Roadside LPG sales in Africa.
View specificationsSpecial purpose trucks for export buyers worldwide
CHENGLIWEI TRUCK CATALOG
Browse LPG skid-station and filling-plant listings for defined dispensing or filling operations. Compare the vessel, pump, measurement equipment, controls and installation scope as an itemised package. Send the container type, daily and peak demand, supply method, site dimensions and destination so the proposed system can be reviewed against the actual project.
CHENGLIWEI
Chengliwei mobile LPG auto filling station: dispenser, 5-30m3 propane tanks, 1.77 MPa, free spares for 12 months. Roadside LPG sales in Africa.
View specifications
CHENGLIWEI
Mini LPG skid station kit for wharves, ports and bus stations: 5-200 cbm tanks, Q345R, 1.77 MPa design pressure, 20-year design life. Video support.
View specifications
CHENGLIWEI
Chengliwei LPG filling station with LPG dispenser and low-pressure propane vessel, 1.77 MPa design pressure. Spare parts free for 12 months.
View specifications
CHENGLIWEI
Small cooking gas station with a 10m3 propane tank, LPG dispenser and free spare parts for 12 months. Suits local refill points.
View specifications
CHENGLIWEI
Portable LPG skid refilling station: 10m3 Q345R tank, 3990 kg payload, YB15-15 pump, ZW-0.95/10-15 compressor. Fits town gas depots in South Africa.
View specifications
CHENGLIWEI
Chengliwei mobile LPG skid station in 10-40m3 sizes. Sample tank: 10m3, 345R steel, 10 mm walls, 2950 kg, low pressure, 1.77 MPa design.
View specifications
CHENGLIWEI
Chengliwei LPG skid station with dispenser: 2950 kg tank weight, 3990 kg payload, 1.77 MPa design pressure. For gas distributors in West Africa.
View specifications
CHENGLIWEI
LPG cylinder filling station: 10-30m3 skid tank, dispenser, 345R vessel at 1.77 MPa. Spare parts free for 12 months. For cooking gas retailers in Africa.
View specifications
CHENGLIWEI
LPG gas filling plant with 10-15 ton storage, LPG dispenser, 1.77 MPa design pressure and free spare parts for 12 months. For gas marketers in Africa.
View specifications
CHENGLIWEI
Chengliwei mobile LPG filling plant with 5-10 ton storage, LPG dispenser, low-pressure propane vessel and free spare parts for 12 months.
View specifications
CHENGLIWEI
10000L bullet tank LPG skid station with dispenser: low-pressure storage vessel, 345R carbon steel, 1.77 MPa design pressure. Ask for a quote.
View specifications
CHENGLIWEI
Mobile LPG skid with a 10m3 Q345R propane tank (2950 kg), 3990 kg payload, LPG pump and compressor. Suits LPG retailers in East Africa.
View specifications
CHENGLIWEI
LPG skid station, 5260 x 1620 x 2210 mm overall, with YB15-15 LPG pump, Kaiyuan scale and ZW-0.95/10-15 compressor. Scale or dispenser option.
View specifications
CHENGLIWEI
Mobile LPG skid plant with LPG scale and a Q345R carbon steel propane tank in 10-40m3 range, low pressure 0.1-1.6MPa. Spare parts free for 12 months.
View specifications
CHENGLIWEI
LPG cylinder filling plant with scale: 10m3 propane skid tank, 10 mm shell and ends, 3990 kg payload, 1.77 MPa design pressure. Ask for a quote.
View specifications
CHENGLIWEI
10000L mobile LPG filling skid, medium-pressure vessel in Q345R/SA516 steel, J41N-2.5-80 cut-off valve and WTQ-280 thermometer. Ask for a quote.
View specifications
CHENGLIWEI
Mobile LPG skid filling station: Q345R carbon steel propane vessel, 10 mm plate, 1.77 MPa design pressure, 2950 kg tank. Ask for a quote.
View specificationsDefine the filling task and throughput before selecting equipment. Cylinder filling and vehicle dispensing are different operations, and the quotation should name the included vessel, pump, metering or weighing equipment, controls and installation interfaces. A compact layout still needs a site-specific review.
This category lists about 17 LPG skid and mobile filling stations. Tanks run from about 5 m³ to 50 m³ (about 2 to 25 t of LPG). Most come with a pump and a dispenser for autogas or a scale for cylinder filling, mounted on one skid.
| Type | Tank size | Typical use |
|---|---|---|
| Mini and small skid | about 5 to 10 m³ | Small cylinder filling and remote sites |
| Standard skid with dispenser | about 10 to 30 m³ | Autogas and cylinder filling |
| Large skid or filling plant | about 30 to 50 m³ | Cylinder filling plants and depots |
Figures are approximate ranges taken from the model pages in this category. The exact capacity, chassis and equipment are confirmed in the quotation.
Request an itemised equipment list and a clear boundary between factory-supplied equipment and site work, including foundations, connections, power and commissioning responsibilities.
Daily volume is a starting point. Also provide peak demand, filling quantities, replenishment frequency and the available working area.
No. The filling connection, measurement and operating arrangements differ. Specify the intended operation before comparing station packages.
Related categories: LPG Storage Tanks · LPG Bobtail & Tanker Trucks · Request a quotation
Share your destination, quantity and preferred configuration when requesting a quote.
How a skid-mounted LPG filling station differs from a fixed site, and the questions to settle before you ask for a quotation for an LPG refilling or loading station.
An LPG filling station stores liquid gas and transfers it into cylinders or vehicles using a tank, pump, dispenser and safety devices. See the parts and how to plan one.
Fixed and skid-mounted LPG storage tanks from 5 to 120 m³, plus skid filling stations for cylinder refilling, with listed models, sizes and reference prices.
Build an LPG filling-station spare-parts register from the supplied equipment plates and manuals. Separate identification and procurement from work reserved for qualified maintenance personnel.
Prepare a project brief for a qualified LPG design team before selecting filling equipment. Record demand, cylinder types, land information, vehicle access and available utilities.
Break an LPG filling-station offer into vessel, transfer, weighing, controls and site-work scope. A list of equipment does not establish a complete approved operating installation.